805 Relay 12 Volt

$31.35 inc GST

The 805 will switch Over bed Luminaries in Hospital environments by interfacing to the Patient
handset contacts.  It comprises an electronic latching circuit switching a mechanical relay to
achieve reliable, interference free switching of Over bed lights including CFL, Incandescent and
Fluorescent luminaries.

Specifications  

Physical 
Size 55 x 40 x 36 mm approx with mounting flanges
Case PVC (electrical fire resistant tested)
Mounting Flanges for mounting on 65mm centres

Electrical switching  
Mains Connection Pluggable Screw Connector 3 way (supplied)
Contacts NO/Com/NC Changeover contacts 12 Amps
Rating Contacts 12 Amp Mains rated Industrial Switching
Voltage 240 VAC mains to be installed in accordance with AS3000

Input
Input connections Pluggable Screw Connector 3 way (supplied)
Trigger Momentary
Trigger type Factory set – user changeable Positive or Negative
Trigger Polarity Negative or Positive by NO contacts
Trigger Current 10mA Pulse 200mS minimum
Re-trigger time minimum 800mS between triggers
DC voltage Nominal 12 or 24 volt
DC Current (ON) 43mA for 12 volt – 22mA for 24 volt
DC Current (Off) 6.5 mA for 12 volt – 5mA for 24 volt Approval Test Report

Approvals
Registration Number – Q03405

SKU: VT-805 12v. Categories: , .