804 Relay 12 Volt
804 Relay 12 Volt

The 804 is intended to switch overbed luminaries in Hospital environments by interfacing to the
Patient handset contacts.  It comprises an electronic latching circuit that switches a mechanical
relay to achieve reliable, interference free switching of Overbed lights including CFL and
Flourescent luminaires.

Specifications 

Physical
Size 51 x 30 x 25 mm
Case PVC (electrical fire resistant test)
Mounting Flanges on 60mm centres

Electrical Switching
Mains Connection
Pluggable Screw Connector 2 way (supplied)
Rating 1.0 Amp (contacts 10 Amp resistive)
Voltage 240 VAC mains must be installed in accordance with AS3000

Input
Input connections Pluggable Screw Connector 3 way (supplied)
Trigger Momentary
Trigger type Factory set – user changeable Positive or Negative
Trigger Polarity Negative or Positive by NO contacts
Trigger Current 10mA Pulse 200mS minimum
Retrigger time minimum 800mS between triggers
DC voltage Nominal 12 or 24 volt
DC Current (ON) 43mA for 12 volt – 22mA for 24 volt
DC Current (Off) 6.5 mA for 12 volt – 5mA for 24 volt

Approvals
Energex Queensland NATA Lab. Test report 02/AL/174 Registration Number Q03405

$31.35 inc GST Add to cart
804 Relay 24 Volt
804 Relay 24 Volt

The 804 is intended to switch overbed luminaries in Hospital environments by interfacing to the Patient handset contacts. It comprises an electronic latching circuit that switches a mechanical relay to achieve reliable, interference free switching of Overbed lights including CFL … Read More

$31.35 inc GST Add to cart
805 Relay 12 Volt
805 Relay 12 Volt

The 805 will switch Over bed Luminaries in Hospital environments by interfacing to the Patient
handset contacts.  It comprises an electronic latching circuit switching a mechanical relay to
achieve reliable, interference free switching of Over bed lights including CFL, Incandescent and
Fluorescent luminaries.

Specifications  

Physical 
Size 55 x 40 x 36 mm approx with mounting flanges
Case PVC (electrical fire resistant tested)
Mounting Flanges for mounting on 65mm centres

Electrical switching  
Mains Connection Pluggable Screw Connector 3 way (supplied)
Contacts NO/Com/NC Changeover contacts 12 Amps
Rating Contacts 12 Amp Mains rated Industrial Switching
Voltage 240 VAC mains to be installed in accordance with AS3000

Input
Input connections Pluggable Screw Connector 3 way (supplied)
Trigger Momentary
Trigger type Factory set – user changeable Positive or Negative
Trigger Polarity Negative or Positive by NO contacts
Trigger Current 10mA Pulse 200mS minimum
Re-trigger time minimum 800mS between triggers
DC voltage Nominal 12 or 24 volt
DC Current (ON) 43mA for 12 volt – 22mA for 24 volt
DC Current (Off) 6.5 mA for 12 volt – 5mA for 24 volt Approval Test Report

Approvals
Registration Number – Q03405

$31.35 inc GST Add to cart
805 Relay 24 Volt
805 Relay 24 Volt

The 805 will switch Over bed Luminaries in Hospital environments by interfacing to the Patient handset contacts. It comprises an electronic latching circuit switching a mechanical relay to achieve reliable, interference free switching of Over bed lights including CFL, Incandescent … Read More

$31.35 inc GST Add to cart
806 Relay
806 Relay

The 806 Relay was designed to fulfill a specific need for a over bed latching relay that would operate from a mains power supply and trigger with an isolated low voltage momentary pulse.

The 806 relays are fitted into a grey PVC case 55 x 40 x 30 mm. They may be mounted inside light fittings using self tapping screws and terminated at a 3 way mains terminal strip. The input wire is a low voltage cat 5 style cable terminated at the relays input wires. The relays comprise a printed circuit board with all components soldered. There are no user serviceable components inside.

Specifications 

Power requirements Mains active and Neutral at a quiescent current of 10 milliamps.
Output: Active switched by mechanical relay contacts, rated at 1Amp 240 VAC.
Input: A momentary trigger signal of 12 volts (nominal ) which will supply 10 milliamps. Polarity is not important.
Input is optically isolated from mains.

Connections
Output: By three way pluggable terminal strip
Inputs: Are by two way pluggable terminal strip. Polarity is unimportant.

$31.35 inc GST Add to cart